Calculite® HID Downlight C6E17OVW  
Page 1 of 2  
6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam  
Ceiling Cutout: 6 9/16” (167 mm) Dia.  
Reflector Trim  
Frame-In Kit  
Lamp (Coated, Ceramic MH)  
C6E17OVW CLW  
Specular Clear, White Painted Flange.  
C670MHOE1 Electronic, 120V  
C670MHOE2 Electronic, 277V  
C610MHOE1 Electronic, 120V  
C610MHOE2 Electronic, 277V  
70W E17, ED17, BD17 (Open Rated)  
70W E17, ED17, BD17 (Open Rated)  
100W E17, ED17, BD17 (Open Rated)  
100W E17, ED17, BD17 (Open Rated)  
CLP  
Specular Clear, Matching Flange.  
CCDW  
Comfort Clear Diffuse, White Painted Flange.  
Comfort Clear Diffuse, Matching Flange.  
Champagne Bronze, White Painted Flange.  
Champagne Bronze, Matching Flange.  
CCDP  
CCZW  
CCZP  
C670MHOU Magnetic, 120V/277V 70W E17, ED17, BD17 (Open Rated)  
C610MHOU Magnetic, 120V/277V 100W E17, ED17, BD17 (Open Rated)  
Electrical (cont)  
Features  
Ballast  
ANSI Code Voltage  
Max. Amps Input Watts  
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide  
beam distribution.  
70W MH M98/M139  
100W MH M90/M140  
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,  
HX-HPF circuit type, high power factor, sound rating “B, -20°F minimum starting  
temperature, Type 1 Outdoor rating.  
120/277  
120/277  
0.67/0.29  
0.90/0.43  
78  
110  
2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image; self-  
flange in painted white or aperture-matching polished flange. Consult  
factory for other finishes.  
3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated socket.  
Snaps onto upper reflector for secure attachment without tools; unitized con-  
struction assures proper lamp alignment to optics for consistent performance.  
4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed  
mounting bars.  
Ballast  
ANSI Code Voltage Max. Amps Input Watts  
70W MH M98/M143 120/277 1.90/0.80  
100W MH M90/M140 120/277 0.90/0.43  
94  
125  
Options and Accessories  
5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical  
adjustment from above or below for ceilings from 0" to 2" thick. Center-line  
notches allow consistent alignment of multiple fixtures.  
6. Aperture Cone Retention Springs: Rust resistant springs secure cone in  
place for quick, tool-less installation.  
7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism  
accommodates mounting to virtually any ceiling system using pre-installed  
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures  
all adjustments. Alignment holes and markings allow fixture to be pre-set  
prior to installation.  
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet “A/E”  
Emergency Lamp: Add suffix E to FIK and Reflector Trim. See Spec.Sheet “A/E”  
Slope Ceiling Adapters: See Specification Sheet SCA.  
Fuse (magnetic ballast): Add suffix F1 or F2 to FIK (F1=120V F2=277V)  
Chicago Plenum: Consult Factory.  
Labels  
UL (Suitable for Damp Locations), CSA, I.B.E.W.  
8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"  
long and lock securely into position. Built-in locking tabs provide positive attach-  
ment to common T-bar systems. Self-centering feature simplifies installation in  
24" O.C. grid systems. Attaches to steel or wood joists without accessories.  
9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).  
Accessible from below for inspection and/or replacement without tools.  
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,  
90°C through branch circuit conductors; allows inspection from below.  
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not  
install insulation above nor within 3" (76mm) of any part of the luminaire.  
Job Information  
Type:  
Job Name:  
Cat. No.:  
Lamp(s):  
Notes:  
Electrical  
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor,  
T.H.D. <15%, thermally and transient protected, RMI / RFI complies with FCC  
Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound  
rating "A", -5°F minimum starting temperature, Type 1 outdoor rating.  
Lightolier a Genlyte Thomas Company  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504  
 

Land Pride Lawn Mower 315 507P User Manual
LG Electronics Microwave Oven LMV1680 User Manual
Life Fitness Home Gym 807 User Manual
Lightolier Indoor Furnishings WB Series 2FT User Manual
Likko MP3 Player LKM01 User Manual
Lindy Computer Hardware 70548 User Manual
Linksys Network Router AG041 EU User Manual
Magnavox TV VCR Combo MWC24T5 User Manual
Makita Cordless Drill DA312DWD User Manual
Marshall electronic Computer Monitor V R151PV R151P User Manual