Menu Information  
Adjustment  
$ Total pedestal level adjustment  
(Use an oscilloscope or a waveform monitor for this  
adjustment.)  
This step is to adjust the black levels (pedestal levels) of two  
or more cameras to be the same.  
[ADJUSTMENT by CAMERA]  
1. Close the lens.  
2. Select Pedestal item in the brightness setting Sub Menu.  
(Select [Pedestal] in the [Iris, Shutter, Gain Set] sub  
menu in User Mode.)  
3. Set the pedestal level to 5 IRE (0.035 V) with the  
YES/ABC switch or the NO/BAR switch.  
NO/BAR switch  
YES/ABC switch  
[ADJUSTMENT with RCU (RCB, Hybrid control panel)]  
Adjust the pedestal level to 5 IRE with the total pedestal  
adjustment.  
TOTAL PEDESTAL  
-26-  
$ Gen-lock adjustment  
Phase adjustments must be performed with the camera or  
the RCU (RCB) when external synchronizing signals are  
supplied to the system in cases where multiple cameras are  
used or peripheral devices are connected.  
U Horizontal phase control  
Observe the waveform of the external synchronizing input  
signal (black burst signal) and video output signal on a  
two-channel oscilloscope. Then match the horizontal phase  
of both signals by adjusting them with the cameras or RCU’s  
horizontal phase control.  
NO/BAR switch  
YES/ABC switch  
[ADJUSTMENT with RCU (RCB, Hybrid control panel )]  
Use the horizontal phase control.  
External gen-lock input signal  
(black burst output of special effect  
generator)  
Video signal  
Adjust the horizontal phase  
[ADJUSTMENT by CAMERA]  
1. Press the NO/BAR switch for over 5 seconds to display  
the color bar.  
Subcarrier phase  
fine control  
Horizontal phase  
control  
2. Select [G/L Adjustment] on the main menu, then select [H  
Phase] on the submenu.  
3. Adjust the horizontal phase with the YES/ABC and  
NO/BAR switch.  
Subcarrier phase  
coarse control  
-27-  
Adjustment  
Caution:  
4. Select [SC Fine] on the sub menu. Perform fine  
adjustment with the YES/ABC switch and the NO/BAR  
switch.  
• When horizontal phase adjustment is required using RCU  
(RCB) or hybrid control panel, BAR/CAM switch should be  
set to BAR. Horizontal phase cannot be adjusted if the  
switch is in the CAM position. After adjustment set  
BAR/CAM switch back to CAM.  
• When horizontal phase adjustment is moved, color phase  
is also moved. Adjust color phase whenever horizontal  
phase adjustment is moved.  
U Color phase adjustment  
Supply the output signal (split color bar) from the color  
special effect generator to a color monitor or vectorscope.  
Adjust the color phase of the camera.  
[ADJUSTMENT with RCU (RCB, Hybrid control panel)]  
Use the subcarrier phase coarse adjustment control and  
subcarrier phase fine control.  
It is recommended that a vectorscope be used for  
maximum accuracy in color phase adjustment.  
Color bar of camera  
Sprit line  
Color bar of special  
effects generator  
Caution:  
• When color phase adjustment is required using RCU  
(RCB) or hybrid control panel, BAR/CAM switch should be  
set to BAR. Color phase cannot be adjusted if the switch is  
in the CAM position. After adjustment set BAR/CAM switch  
back to CAM.  
• When horizontal phase adjustment is moved, color phase  
is also moved. Adjust color phase whenever horizontal  
phase adjustment is moved.  
[ADJUSTMENT by CAMERA]  
1. Press the NO/BAR switch for over 5 seconds for the color  
bar mode.  
2. Select [G/L Adjustment] on the main menu, then select  
[SC Coarse] on the sub menu.  
3. Make coarse adjustment with the YES/ABC switch and  
the NO/BAR switch.  
-28-  
Use mode setting  
2. Press the MENU switch, ITEM/AWC switch, or NO/BAR  
switch to let the desired use mode blink.  
MENU switch (A):  
$ Use Mode Setting  
The camera has four use modes, and various functions for  
four use modes have been preset.  
The blinking item moves up by one.  
ITEM/AWC switch (S), NO/BAR switch (–):  
The blinking item moves down by one.  
Functions can be set as best suited to each use mode.  
• Halogen mode  
Suited to indoor shooting, such as at weddings, parties,  
lecture meetings, events, etc.  
Settings can be changed using a simple menu.  
• Fluorescent mode  
Suited to indoor shooting under fluorescent lighting.  
Settings can be changed using a simple menu.  
• Outdoor mode  
Suited to outdoor shooting.  
Settings can be changed using a simple menu.  
• User mode  
Settings can be changed using a detail menu.  
3. Press the YES/ABC switch.  
The blinking use mode comes into effect. After the use  
mode setting menu is shown for about 5 seconds, the  
camera returns to be ready for operation.  
$ Setting by camera  
Then, the camera operates in the selected use mode.  
1. Turn the camera on while keeping the MENU switch  
depressed.  
The use mode setting menu shown at right appears on  
the monitor screen and one of the use mode blinks.  
-29-  
Use mode setting  
$ Setting by RCU (RCB) or hybrid control  
panel  
An operation mode is selected depending on the position of  
the scene file switch.  
Scene File Switch Scene File Switch  
Operation mode  
Position of  
Position of Hybrid  
RCU (RCB)  
control panel  
Halogen Mode  
Fluorescent Mode  
Outdoor Mode  
User’s Mode  
1
1
2
3
4
2
3
USER SET  
CAMERA  
RCU (RCB)  
Hybrid control panel  
MENU  
ITEM/AWC  
YES/ABC  
NO/BAR  
SCENE  
FILE switch  
SCENE FILE switch  
-30-  
Menu item setting  
U Main menu screen  
Main menu of Halogen,  
$ Menu item setting  
• Each of the four use modes of the camera has a main  
menu. (Shown at right)  
Fluorescent, Outdoor Mode  
• Each item of the main menu has a submenu, which  
consists of several settings.  
Use mode  
Blinking  
• These settings have been preset to the optimum values to  
suit each use mode, and can be changed to suit actual  
shooting conditions.  
• They can be set from the camera and RCU (RCB). They  
can also be set from the hybrid control panel using the  
switches, but the setting items are limited because the  
menu is not shown.  
Notes:  
• Composite signals are output from the video output  
regardless of the position ENC/VF of the RCU (RCB) user  
set switch.  
Main menu of User Mode  
• [End] is displayed only in setting from the camera alone.  
• [Option Card1] is shown only when an optional card is  
inserted into the camera. [Option Card2] is shown only  
when an additional card box is equipped with the camera  
and then an optional card is inserted into the camera.  
-31-  
Menu item setting  
If the output signal from camera is color bar, only “G/L,  
6. Select [Return] using the MENU switch and ITEM/AWC  
switch, then press the YES/ABC switch to return to the  
main menu.  
Color Bar Set” screen is displayed.  
7. After changing the settings, take the following steps.  
Camera alone:  
Select [End] using the MENU switch and ITEM/AWC  
switch and press the YES/ABC switch.  
RCU (RCB):  
Set the user set switch in the pocket to the OFF position.  
The camera will now operate according to the new settings.  
CAMERA  
RCU (RCB)  
USER SET switch  
MENU  
$ Setting  
ITEM/AWC  
YES/ABC  
NO/BAR  
1. From the camera alone:  
Keep the MENU switch depressed for 5 seconds or more.  
From RCU (RCB):  
Set the user set switch in the pocket to the ON position.  
The main menu appears on the monitor screen.  
2. Each time the MENU switch (A), ITEM/AWC switch (S),  
or NO/BAR switch (–) is pressed, the blinking item moves  
up or down.  
$ Changing the Language setting  
The language on the menu screen can be changed from  
English to Japanese. (Factory setting: English)  
• Halogen, Fluorescent, Outdoor Mode  
Select “Japanese” in the “Language” setting in Other Set  
submenu.  
3. When the YES/ABC switch is pressed after selecting the  
desired item to blink, the submenu for the selected item  
appears on the screen.  
4. Select the desired item to be changed in its settings using  
• Use Mode  
the MENU switch (A) and ITEM/AWC switch (S).  
Select “Japanese” in the “Language” setting in Other Set2  
submenu.  
5. Press the YES/ABC switch (+) or NO/BAR switch (–) to  
change the settings.  
-32-  
$ Sub menu (Halogen Mode, Fluorescent Mode, Outdoor Mode)  
1Brightness Set Display  
3G/L, Color Bar Set Display  
5Other Set Display  
1–––––  
2–––––  
3–––––  
4–––––  
5–––––  
6––––––  
7–––––  
8–––––  
=–––––  
>–––––  
?–––––  
@–––––  
A––––  
G–––––  
H–––––  
I––––––  
J–––––  
K–––––  
L–––––  
M–––––  
N–––––  
O–––––  
2Color Set Display  
4Sharpness (DTL) Set Display  
9–––––  
:–––––  
;–––––  
<––––––  
B–––––  
C––––––  
D–––––  
E–––––  
F–––––  
• Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.  
• Settings enclosed in [ ] is displayed when the optional card to process video signals (SDI card, etc.) is inserted.  
• To return to the initial settings, refer to page 53.  
-33-  
Menu item setting  
R/L cut: About one-third of both the right and left  
portions of the screen are excluded from  
measurement.  
$
Setting and changing of the setting (Halogen  
Mode, Fluorescent Mode, Outdoor Mode)  
1Brightness Set Display  
1 Video Level Adjustment [Picture Level: –50 to +50]  
Convergence level of AUTO IRIS/AUTO GAIN UP/ AUTO  
ND (ELC) can be adjusted.  
4 Auto ND (ELC) Setting [Auto ND (ELC): OFF, ON]  
OFF: Luminance is not automatically adjusted by the  
electronic shutter.  
ON: The electronic shutter is controlled to automatically  
adjust the luminance.  
2 Detecting Ratio Adjustment  
[Light PEAK/AVG: P50 to A50]  
The ratio of AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC)  
detected peak to average can be adjusted within a  
predetermined range.  
Notes  
• ON is automatically selected when the electronic shutter  
(H) on the submenu [Other Set] is set to [Auto ND].  
OFF is selected when other than [Auto ND] is selected.  
3 Photometric Measurement Method Setting  
[Light Area: All, Center, Top cut, BTM cut, R/L cut]  
A photometric measurement method can be selected for  
AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC).  
• ON is selected when the SHUTTER switch is set to  
[ELC] in RCU (RCB) mode, and OFF is selected when it  
is set to other than [ELC].  
All:  
All the screen area is measured.  
Center: The screen is measured mainly in the center  
area, about one-third of both the top and  
bottom and one-third of both the right and left  
portions of the screen are excluded from  
measurement.  
Top cut: About one-third of the top part of the screen is  
excluded from measurement.  
BTM cut: About one-third of the bottom portion of the  
screen is excluded from measurement.  
SHUTTER switch  
RCU (RCB)  
-34-  
5 Auto Gain Up Control Setting [Auto Gain Up: OFF, ON]  
6 AGC Maximum Gain [AGC Max Gain: 6dB, 12dB,  
18dB, 24dB, N/Eye L, N/Eye H]  
OFF: The light quantity is not adjusted  
automatically.  
ON: The light quantity is adjusted automatically.  
The maximum to which the gain can be increased  
using the auto gain up function is selected by the  
AGC maximum gain setting (6).  
This is used to set the maximum amount to which the  
gain can be increased when “ON” has been selected as  
the auto gain up setting (5).  
7 Manual Gain Up Control Setting  
[Manu Gain Up: 0 dB to 30 dB, N/Eye L, N/Eye H]  
Manual setting is possible only when the Auto Gain Up  
control is in the OFF position.  
Notes  
• In case of settings on the camera alone or when the iris  
switch on the RCU (RCB) is at [AUTO], the Auto Gain  
Up control may not operate if the lens iris switch is in  
the manual position.  
0 dB:  
0 dB should be selected in normal cases.  
1 dB to 30 dB: Use this range if sufficient video output  
cannot be obtained even when the lens  
iris is opened in shooting dark scenes.  
N/Eye L (Night Eye L):  
• When the AGC switch on the hybrid control panel is set  
to AGC, the Auto Gain Up control operates in the HIGH  
position.  
Use this mode if sufficient video output  
cannot be obtained even if 30 dB gain up  
should be selected.  
AGC switch  
N/Eye H (Night Eye H):  
Use this setting if it is not possible to  
achieve a satisfactory video output even  
at the Night Eye L setting.  
Hybrid control panel  
-35-  
Menu item setting  
Notes  
2Color Set Display  
• Only 0 dB, 9 dB, or 18 dB can be selected in case of  
using the RCU (RCB).  
9 Chroma Level Adjustment [Chroma Level: –3 to +3]  
Chroma Level can be decreased or increased to any of  
three levels each.The signal output to the optional card  
cannot be adjusted.  
• 0 dB when the manual GAIN switch on the hybrid  
control panel is at LOW, 9 dB when it is at MID, or  
18 dB when it is at HIGH.  
: Skin Color Adjustment [Flesh Tone: –3 to +3]  
Skin color can be decreased or increased to any of three  
levels each.  
Manual GAIN switch  
; White Balance Setting  
[White Bal: ATW, AWC A, AWC B, 3200K, 5600K]  
ATW: The white balance is automatically adjusted to  
be always right.  
Hybrid control panel  
AWC A, AWC B:  
Once the white balance is adjusted with the  
ITEM/AWC switch on the back of the camera, it  
is no longer necessary to set the white balance  
again if you simply select AWC A or AWC B,  
provided that the camera is used under the same  
conditions.  
8 Black Level Setting [Pedestal: –150 to +150]  
The black level (pedestal) of the luminance (Y) signal can  
be set. Used in adjusting the black levels of two or more  
cameras.  
Fine color adjustment can be made after setting  
AWC by red/blue gain adjustment in user mode  
or from the RCU (RCB).  
3200K: The white balance is adjusted to 3200K  
illumination.  
-36-  
5600K: The white balance is adjusted to 5600K  
3G/L, Color Bar Set Display  
illumination.  
= Horizontal Phase Adjustment [H Phase: –206 to +49]  
Horizontal phase can be adjusted when a genlock signal  
is supplied.  
Note  
Neither 3200K nor 5600K can be set from the RCU  
(RCB) or the hybrid control panel.  
> Subcarrier Phase Coarse Adjustment  
[SC Coarse: 1, 2, 3, 4]  
Coarse adjustment of subcarrier phase can be made  
when a genlock signal is supplied.  
< ATW Speed Setting  
[ATW Speed: Slow 2, Slow 1, Mid, Fast 1, Fast 2]  
ATW Speed can be set.  
? Subcarrier Phase Fine Adjustment  
[SC Fine: –511 to +511]  
Fine adjustment of subcarrier phase can be made when a  
genlock signal is supplied.  
@ Color Bar Setup Setting  
[Color Bar Set: 0.0 IRE, 7.5 IRE]  
The setup level of color bar can be adjusted.  
A Color Bar Setup Setting for the optional cards  
[Color Bar Set2: 0.0 IRE, 7.5 IRE]  
This menu is displayed when the optional card to process  
video signals is inserted.  
The setup level of color bar to output to the optional card  
can be adjusted.  
Set 0.0 IRE when the SDI card is inserted.  
-37-  
Menu item setting  
D Noise Suppress Level Setting  
[Noise Suppress: OFF, Low, High]  
Screen noise can be reduced when Detail Level setting is  
at High or Low.  
4Sharpness (DTL) Set Display  
B
Detail Select Setting [DTL Select: Sharpness, Super DTL]  
If contour correction is not sufficient at the Sharpness  
position when Detail Level setting is set to Low or High,  
select the Super DTL position.  
E Clean DNR Setting [Clean DNR: OFF, Low, High]  
Note  
This enables the clean DNR effect to be selected.  
Neither Sharpness nor Super DTL is valid for contour  
correction if Detail Level setting is in the OFF position.  
F Flesh Noise Suppress Level Setting  
[Flesh Noise Sup.: OFF, Low, High]  
Flesh noise is suppressed in two steps when the Detail  
Level Setting is at High or Low.  
C Detail Level Setting [Level: OFF, Low, High]  
Detail level can be adjusted when Detail Select setting is  
at Sharpness. Super DTL level can be adjusted when it is  
at Super DTL.  
In case of using the RCU (RCB), the above can be  
adjusted with the contour correction switch (DTL).  
RCU (RCB)  
DTL switch  
-38-  
I Electronic Shutter Synchro Scan Setting  
[Synchro Scan: 60.34Hz to 15.75kHz]  
5Other Set Display  
G Contrast Adjustment  
This setting is possible only when Electronic Shutter  
setting is at S/Scan.  
Horizontal bar noise can be reduced by synchro-scan  
adjustment in shooting workstation scenes, for example.  
For luminance settings at each shutter speed and  
synchro-scan shutter speed, refer to the table below.  
[Contrast (Gamma): Low, Mid, High]  
Contrast can be adjusted to any of three levels.  
H Electronic Shutter Setting [Shutter Speed: OFF, 1/100  
to 1/10000, S/Scan, Auto ND]  
Shutter Speed  
Synchro-scan  
Required luminance ratio  
OFF:  
Electronic shutter is turned off.  
OFF  
1
2
1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:  
Electronic shutter operates at one of these  
speeds as selected.  
1/100  
100.3 Hz  
250.0 Hz  
492.2 Hz  
984.4 Hz  
1.969 kHz  
3.938 kHz  
7.875 kHz  
1/250  
4
S/Scan (Synchro Scan):  
1/500  
8
Electronic shutter operates at the speed set  
with the electronic shutter synchro-scan setting.  
Auto ND: Electronic shutter is controlled to automatically  
adjust the luminance.  
1/1000  
1/2000  
1/4000  
1/10000  
16  
32  
64  
160  
Notes  
J CCD Read Out Mode Setting  
In case of using the RCU (RCB), none of the shutter speeds  
— 1/250, 1/2000, 1/4000, and 1/10000 can be selected.  
[V Resolution: Normal, Fine]  
Normal: Normal image. (CCD storage will be by field  
• In case of using the hybrid control panel, only OFF,  
1/100, or Auto ND (ELC) can be selected.  
storage.)  
Fine:  
Vertical resolution increases. (Vertical resolution  
is raised without increasing residual images by  
frame storage and Electronic shutter.)  
Normal is recommended for general use  
because sensitivity will decrease at the Fine  
setting.  
If the lens iris switch is at M (Manual) when operating the camera  
alone or when the iris switch on the RCU (RCB) is at AUTO, Auto  
ND may not function. Set the lens iris switch to A (Auto).  
Flickering may increase at Auto ND under fluorescent lights.  
• Auto ND is automatically selected if Auto ND (ELC)  
setting is set to ON.  
-39-  
Menu item setting  
K PC Control Access Speed Setting  
[Baud Rate: 1200bps, 2400bps, 4800bps, 9600bps]  
Select a communication speed in controlling the camera  
from the computer.  
O Language Selection [Language: English, Japanese]  
English: Menu screen is displayed in English.  
Japanese: Menu screen is displayed in Japanese.  
L Component Output Setting  
[Component: RGB, Y/Pr/Pb, Y/C]  
This enables RGB, Y/Pr/Pb or Y/C to be selected as the  
component signals which are to be output from the I/F  
REMOTE connector.  
M Aspect Ratio Selection [Aspect Ratio: 16:9, 4:3]  
Aspect ratio can be selected from 16:9 or 4:3.  
N Fan Setting [Fan SW: OFF, Auto]  
OFF: Select this setting to stop the fan when its  
operating sound is found to be bothersome in a  
studio or other such environment.  
Auto: The temperature is detected automatically, and  
the fan starts operating when the temperature  
exceeds approx. 95°F (35°C).  
Under normal circumstances, the “Auto” setting is  
used.  
-40-  
$ Sub menu (User Mode)  
6Iris, Shutter, Gain Set Display 8G/L, Color Bar Set Display  
9Detail Set Display  
P–––––  
Q–––––  
R–––––  
S–––––  
T–––––  
U–––––  
V–––––  
W––––––  
]–––––  
^–––––  
_–––––  
`–––––  
a––––  
b–––––  
c–––––  
d–––––  
e–––––  
f–––––  
g–––––  
h–––––  
i–––––  
j–––––  
k–––––  
l–––––  
m–––––  
7Color Set Display  
X–––––  
Y–––––  
Z––––––  
[–––––  
\–––––  
-41-  
Menu item setting  
:Color Matrix Set Display  
;Other Set Display  
o–––––  
p–––––  
q–––––  
n–––––  
n–––––  
r––––  
s–––––  
t–––––  
––––  
u–––––  
v–––––  
w–––––  
x–––––  
y–––––  
z–––––  
––––  
• Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.  
• Settings enclosed in [ ] is displayed when the optional card to process video signals (SDI card, etc.) is inserted.  
• To return to the initial settings, refer to page 53.  
-42-  
BTM cut: About one-third of the bottom portion of the  
screen is excluded from measurement.  
R/L cut: About one-third of both the right and left  
portions of the screen are excluded from  
measurement.  
$ Setting and changing of the setting  
items (User Mode)  
6Iris, Shutter, Gain Set Display  
P Video Level Adjustment [Picture Level: –50 to +50]  
Convergence level of AUTO IRIS, AUTO GAINUP, ELC  
can be adjusted.  
Q Detecting Ratio Adjustment  
S Auto Iris Level Fine Adjustment  
[Light PEAK/AVG: P50 to A50]  
[Auto Iris Adjust: OFF, ON]  
The ratio of AUTO IRIS, AUTO GAINUP, ELC detected  
peak to average can be adjusted within a range.  
OFF: The iris control is invalid when the iris switch on the  
RCU (RCB) or on the hybrid control panel is in the  
AUTO position.  
ON: Fine adjustment of auto iris convergence level can  
be made with the iris control when the iris switch  
on the RCU (RCB) or on the hybrid control panel is  
in the AUTO position.  
R Photometric Measurement Method Setting  
[Light Area: All, Center, Top cut, BTM cut, R/L cut]  
A photometric measurement method can be selected for  
AUTO IRIS, AUTO GAINUP, ELC.  
All:  
All the screen area is measured.  
RCU (RCB)  
Center: The screen is measured mainly in the center  
area, about one-third of both the top and  
bottom and one-third of both the right and left  
portions of the screen are excluded from  
measurement.  
Top cut: About one-third of the top portion of the screen  
is excluded from measurement.  
Iris control  
Iris switch  
-43-  
Menu item setting  
• When “Synchro Scan” has been selected as the  
electronic shutter mode setting:  
T Electronic Shutter Mode Setting  
[Shutter Mode: Step, S/Scan, ELC]  
Bar noise can be reduced by synchro-scan adjustment  
in shooting workstation scenes, for example.  
Step: Electronic shutter operates at the speed selected  
by the Electronic Shutter Step/Synchro Scan  
Setting.  
For luminance setting at each shutter speed and synchro-  
scan shutter speed, refer to the table below.  
S/Scan (Synchro Scan):  
Electronic shutter operates at the speed selected  
in Electronic Shutter Step/Synchro Scan Setting.  
ELC: Electronic shutter is controlled to automatically  
Shutter Speed  
OFF  
Synchro-scan  
Required luminance ratio  
1
2
1/100  
100.3 Hz  
250.0 Hz  
492.2 Hz  
984.4 Hz  
1.969 kHz  
3.938 kHz  
7.875 kHz  
adjust the luminance.  
1/250  
4
Note  
1/500  
8
If Frame 1 is selected in CCD Read Out Mode Setting  
(u), Electronic Shutter Mode Setting cannot be added.  
1/1000  
1/2000  
1/4000  
1/10000  
16  
32  
64  
160  
U Electronic Shutter Step/Synchro Scan Setting  
[Step/Synchro: OFF, 1/100 to 1/10000 (Step),  
60.34 Hz to 15.75kHz (Synchro Scan)]  
Notes  
• In case of using the RCU (RCB), none of the shutter  
speeds — 1/250, 1/2000, 1/4000, and 1/10000 can be  
selected.  
This setting is possible only when Step or Synchro Scan  
is selected in Electronic Shutter Mode Setting.  
• When “Step” has been selected as the electronic  
shutter mode setting:  
• In case of using the hybrid control panel, only OFF,  
1/100, or ELC can be selected.  
OFF: Electronic shutter is turned off.  
1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:  
Electronic shutter operates at one of these  
speeds as selected.  
• If the lens iris switch is at M (Manual) when operating  
the camera alone or when the iris switch on the RCU  
(RCB) is at AUTO, ELC may not function. Set the lens  
iris switch to A (Auto).  
• Flickering may increase at ELC under fluorescent lights.  
-44-  
V Gain Setting  
Notes  
[Gain: Auto, 0 dB to 30 dB, N/Eye L, N/Eye H]  
• Only 0 dB, 9 dB, or 18 dB, AGC LOW, AGC HIGH can  
be selected in case of using the RCU (RCB).  
If the lens iris switch is at MANUAL, when operating the  
camera alone or when the iris switch on the RCU (RCB,  
Hybrid control panel) is at AUTO, AGC may not  
function.  
Auto:  
The light quantity is adjusted  
automatically.  
0 dB:  
0 dB should be selected in normal cases.  
1 dB to 30 dB: Use this range if sufficient video output  
cannot be obtained even when the lens  
iris is opened in shooting dark scenes.  
N/Eye L (Night Eye L):  
• AGC HIGH when the AGC selection switch on the  
hybrid control panel is at AGC.  
• 0 dB when the manual gain switch on the hybrid control  
panel is at LOW, 9 dB when it is at MID, or 18 dB when  
it is at HIGH.  
Use this mode if sufficient video output  
cannot be obtained even if 30 dB gain up  
should be selected.  
N/Eye H (Night Eye H):  
Manual GAIN switch  
AGC switch  
Use this setting if it is not possible to  
achieve a satisfactory video output even  
at the Night Eye L setting.  
Hybrid control panel  
-45-  
Menu item setting  
W AGC Maximum Gain Setting  
7Color Set Display  
[AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye L,  
N/Eye H]  
This is used to set the maximum gain up when “Auto” has  
X Chroma Level Adjustment [Chroma Level: –3 to +3]  
Chroma Level can be decreased or increased to three  
levels. The signal output to the optional card cannot be  
adjusted.  
been selected as the gain setting.  
Y White Balance Setting  
[White Bal: ATW, AWC A, AWC B, 3200K, 5600K]  
ATW: The white balance is automatically adjusted to  
the optimum position.  
AWC A, AWC B:  
Once the white balance is adjusted with the  
ITEM/AWC switch on the back of the camera, it  
is no longer necessary to set the white balance  
again if you simply select AWC A or AWC B,  
provided that the camera is used under the same  
conditions.  
Fine color adjustment can be made after setting  
AWC by red/blue gain adjustment in User Mode  
or from the RCU (RCB).  
3200K: The white balance is adjusted to 3200K  
illumination.  
5600K: The white balance is adjusted to 5600K  
illumination.  
Note  
Neither 3200K nor 5600K can be set from the RCU  
(RCB) or the hybrid control panel.  
-46-  
Z ATW Speed Setting  
[ATW Speed: Slow 2, Slow 1, Mid, Fast 1, Fast 2]  
ATW Speed can be set.  
R/B gain  
control  
R/B pedestal  
control  
[ Black Level Setting [Pedestal: –150 to +150]  
The black level (pedestal) of the luminance (Y) signal can  
be set. Used in adjusting the black levels of two or more  
cameras.  
RCU (RCB)  
\ Painting Setting  
[Painting: R Gain, B Gain, R Pedestal, B Pedestal:  
–150 to +150]  
R Gain, B Gain:  
Fine adjustment of the white balance can be made  
after AWC setting when AWC A or AWC B is  
selected in White Balance Setting. In case of using  
the RCU (RCB), use the R/B gain controls for this  
purpose. The set value returns to 0 after AWC  
setting in using the camera alone.  
R Pedestal, B Pedestal:  
Fine adjustment of the black balance can be made  
after ABC setting.  
In case of using the RCU (RCB), use the R/B  
pedestal controls for this purpose. The set value  
returns to 0 after ABC setting in using the camera  
alone.  
-47-  
Menu item setting  
8G/L, Color Bar Set Display  
9Detail Set Display  
] Horizontal Phase Adjustment [H Phase: –206 to +49]  
Horizontal phase can be adjusted when a genlock signal  
is supplied.  
b Detail Level Setting [Detail: OFF, Low, High]  
Contour correction quantity can be selected.  
Detail settings made using the Horizontal/Vertical Detail  
Level High/Low Setting.  
^ Subcarrier Phase Coarse Adjustment  
[SC Coarse: 1, 2, 3, 4]  
c Horizontal Detail Level High Setting  
Coarse adjustment of subcarrier phase can be made  
[H Detail Level H: L+1 to 63]  
when a genlock signal is supplied.  
d Vertical Detail Level High Setting  
[V Detail Level H: L+1 to 31]  
_ Subcarrier Phase Fine Adjustment  
[SC Fine: –511 to +511]  
e Horizontal Detail Level Low Setting  
[H Detail Level L: 0 to H–1]  
Fine adjustment of subcarrier phase can be made when a  
genlock signal is supplied.  
f Vertical Detail Level Low Setting  
[V Detail Level L: 0 to H–1]  
Detail level can be set in horizontal (H) and vertical (V)  
directions with the Detail Level Setting at High or Low.  
Whichever the direction, H or V, the set level at High  
must be at least one position higher than that at Low.  
` Color Bar Setup Setting  
[Color Bar Set: 0.0 IRE, 7.5 IRE]  
The setup level of color bar can be adjusted.  
a Color Bar Setup Setting for the optional cards  
[Color Bar Set2: 0.0 IRE, 7.5 IRE]  
g Detail Band Setting [Detail Band: 1 to 5]  
A contour correction band can be set with the Detail  
Level Setting at High or Low. The higher setting, the finer  
will be the detail.  
This menu is displayed when the optional card to process  
video signals is inserted.  
The setup level of color bar to output to the optional card  
can be adjusted.  
Set 0.0 IRE when the SDI card is inserted.  
-48-  
h Noise Suppress Level Setting  
l Flesh Noise Suppress Level Setting  
[Flesh Noise Sup.: OFF, Low, High]  
Flesh noise is suppressed in two steps when the Detail  
Level Setting is at High or Low.  
[Noise Suppress: 1 to 10]  
Screen noise can be reduced with the Detail Level  
Setting at High or Low. If the noise suppress level is set  
too high, a fine object will be reproduced less sharply.  
m Precision Detail Level Setting  
[Precision Detail: OFF, Low, High]  
This setting is to narrow detail width and suppress detail  
glare.  
i Level Dependent Level Setting  
[Level Dependent: 0% to 25%]  
Screen noise due to the detail of dark parts of an object  
can be reduced.  
If level dependent level is set too high, however, hair, for  
example, will be reproduced less sharply.  
j Dark Detail Level Setting [Dark Detail: 0 to 5]  
The contours of the darker portions of an object can be  
emphasized.  
This setting is possible only when the Level Dependent  
Level Setting is set to 0%.  
k Chroma Detail Level Setting [Chroma Detail: 0 to 15]  
The contours of high-hue portions of an object can be  
emphasized.  
-49-  
Menu item setting  
G
G
Gain: Increases or decreases the green.  
:Color Matrix Set Display  
Phase: Varies the hue of the green.  
n B_Mg Gain: Increases or decreases the intermediate  
G_Cy Gain: Increases or decreases the intermediate  
color between blue and magenta.  
color between green and cyan.  
B_Mg Phase: Varies the hue of the intermediate color  
G_Cy Phase: Varies the hue of the intermediate color  
between blue and magenta.  
between green and cyan.  
Mg  
Mg  
Gain: Increases or decreases the magenta.  
Cy  
Cy  
Gain: Increases or decreases the cyan.  
Phase: Varies the hue of the magenta.  
Phase: Varies the hue of the cyan.  
Mg_R Gain: Increases or decreases the intermediate  
Cy_B Gain: Increases or decreases the intermediate  
color between magenta and red.  
color between cyan and blue.  
Mg_R Phase: Varies the hue of the intermediate color  
Cy_B Phase: Varies the hue of the intermediate color  
between magenta and red.  
between cyan and blue.  
R
R
Gain: Increases or decreases the red.  
B
B
Gain: Increases or decreases the intermediate  
Phase: Varies the hue of the red.  
color between blue and magenta.  
R_Yl Gain: Increases or decreases the intermediate  
Phase: Varies the hue of the intermediate color  
color between red and yellow.  
between blue and magenta.  
R_Yl Phase: Varies the hue of the intermediate color  
between red and yellow.  
Yl  
Yl  
Gain: Increases or decreases the intermediate  
color of yellow.  
Phase: Varies the hue of the yellow.  
Yl_G Gain: Increases or decreases the intermediate  
color between yellow and green.  
Yl_G Phase: Varies the hue of the intermediate color  
between yellow and green.  
-50-  
v PC Control Access Speed Setting [Baud Rate:  
1200bps, 2400bps, 4800bps, 9600bps]  
;Other Set Display  
o Gamma Level Setting [Gamma: 0.35 to 0.55]  
This setting is to select a communication speed in  
controlling the camera from the computer.  
Gamma correction level can be set.  
p Knee Level Setting  
w Component Output Setting  
[Knee Point: 88% to 98%, Dynamic]  
88% to 98%: The level of video signals subject to knee  
(knee point) can be set.  
[Component: RGB, Y/Pr/Pb, Y/C]  
This enables RGB, Y/Pr/Pb or Y/C to be selected as the  
component signals which are to be output from the I/F  
REMOTE connector.  
Dynamic:  
Knee level is automatically adjusted  
according to the scene.  
x Aspect Ratio Selection [Aspect Ratio: 16:9, 4:3]  
q White Clip Level Setting [White Clip: 95% to 110%]  
The peak level of video signals to be white-clipped can  
be set.  
Aspect ratio can be selected from 16:9 or 4:3.  
y Fan Setting [Fan SW: OFF, Auto]  
OFF: Select this setting to stop the fan when its  
operating sound is found to be bothersome in a  
studio or other such environment.  
Auto: The temperature is detected automatically, and  
the fan starts operating when the temperature  
exceeds approx. 95°F (35°C).  
r Flare Correction Level Setting [Flare R/G/B: 0 to 100]  
Flare correction level can be adjusted.  
s Black Stretch Setting [Black Stretch: ON, OFF]  
Black stretch to correct the suppression of black portions  
at low luminance can be set to ON or OFF.  
Under normal circumstances, the “Auto” setting is  
used.  
t Clean DNR Setting [Clean DNR: OFF, Low, High]  
This enables the clean DNR effect to be selected.  
z Language Selection [Language: English, Japanese]  
u CCD Read Out Mode Setting  
English:  
Menu screen is displayed in English.  
[Field/Frame: Field, Frame 1, Frame 2]  
Japanese: Menu screen is displayed in Japanese.  
Field:  
CCD storage will be by field storage.  
Frame 1: Vertical resolution increases in frame storage.  
Frame 2: Vertical resolution is raised without increasing  
residual images by frame storage and  
-51-  
electronic shutter.  
Setting and changing the optional cards  
3. Safety Zone Setting [Safety Zone: OFF, 1, 2, 3, 4, 5]  
<Optional Card Setting Sub Menu  
This is used to select the type of safety zone which is  
displayed on the viewfinder. A safety zone is not  
displayed when “OFF” is selected.  
This sub menu appears when a studio card (AW-PB305 or  
AW-PB506) has been inserted into the optional card slot.  
The safety zone and center marker indicate electrical  
positions and, as such, they may be at variance with  
their optical positions.  
1 –––––  
2 ––––––  
3 –––––  
4 –––––  
1
4
2
5
3
1. Zebra Indicator Setting [Zebra: OFF, ON]  
This is used to select whether to display the zebra pattern  
on the viewfinder.  
The inside and outside frames denote safety zones of about  
90% and about 95%, respectively.  
OFF: The zebra pattern is not displayed on the  
viewfinder.  
ON: The zebra pattern is displayed on the viewfinder.  
4. EVF Output Setting [EVF Output: Y, CVBS]  
This is used to set the signals to be output to the  
viewfinder.  
2. Zebra Level Setting [Level: 70% to 110%]  
This enables the zebra pattern to be displayed so that it  
will provide as a general guideline for the luminance level.  
It can be set when “ON” has been selected as the  
zebra indicator setting.  
Y:  
The luminance signal is output to the viewfinder.  
CVBS: The color signals are output to the viewfinder.  
When “CVBS” has been selected as the setting, the  
zebra pattern will not be displayed on the viewfinder.  
-52-  
Setting to initial set  
$ Setting to initial set  
In case of the wrong setting in any use mode, take the  
following steps to return to the initial settings.  
(3) If the NO/BAR switch is pressed, or if the YES/ABC  
switch is not pressed, within about 10 seconds, the  
screen shown at 3, and the camera returns to main  
menu, and the existing settings are not initialized.  
(1) Select [Initialize Data] on the main menu screen of each  
Use Mode. (See page 29.)  
Press the YES/ABC switch, then [Initialize Data] screen  
shown for about 10 seconds.  
Note  
(2) Press the YES/ABC switch within about 10 seconds to  
return to the initial settings, the existing settings are  
initialized, the screen shown at 2, and the camera  
returns to main menu.  
If you are using an option card, the Option Card Setting  
Submenu will not be initialized even if “Return to  
Initialize” is performed.  
1
2
3
-53-  
$ Initial settings of the setting items (Factory preset values)  
U Halogen, Fluorescent, Outdoor Mode  
Item  
Halogen mode Fluorescent mode Outdoor mode  
Picture Level  
Light PEAK/AVG  
Light Area  
Auto ND (ELC)  
Auto Gain Up  
AGC Max Gain  
Manu Gain Up  
Pedestal  
0
0
0
0
0
0
Top cut  
OFF  
Top cut  
OFF  
Top cut  
ON  
Brightness  
Set  
OFF  
OFF  
ON  
–––  
–––  
N/Eye H  
–––  
0dB  
0dB  
0
0
–40  
Chroma Level  
Flesh Tone  
White Bal  
0
0
+0  
0
AWC A  
–––  
+0  
0
ATW  
Mid  
Color Set  
AWC A  
–––  
ATW Speed  
H Phase  
0
1
0
1
0
1
SC Coarse  
G/L, Color  
Bar Set  
SC Fine  
Color Bar Set  
Color Bar Set 2  
0
0
0
7.5 IRE  
0.0 IRE  
7.5 IRE  
0.0 IRE  
7.5 IRE  
0.0 IRE  
DTL Select  
Level  
Sharpness  
High  
OFF  
Sharpness  
High  
OFF  
Sharpness  
High  
OFF  
Sharpness  
(DTL) Set  
Noise Suppress  
Clean DNR  
OFF  
OFF  
OFF  
Note  
Flesh Noise Sup.  
OFF  
OFF  
OFF  
When the optional card  
is inserted to the  
camera, “Language”  
menu will not be  
returned to default  
setting even if “Initialize  
Data” menu is executed.  
Contrast (Gamma)  
Shutter Speed  
Synchro Scan  
V Resolution  
Baud Rate  
Mid  
OFF  
Mid  
OFF  
Mid  
Auto ND  
–––  
Normal  
9600bps  
Y/Pr/Pb  
16:9  
–––  
–––  
Normal  
9600bps  
Y/Pr/Pb  
16:9  
Normal  
9600bps  
Y/Pr/Pb  
16:9  
Other Set  
Component  
Aspect Ratio  
Fan SW  
Language  
Auto  
(English)  
Auto  
(English)  
Auto  
(English)  
-54-  
U User Mode  
Item  
User mode  
Item  
User mode  
Picture Level  
Light PEAK/AVG  
Light Area  
0
0
Detail  
High  
20  
19  
13  
8
H Detail Level H  
V Detail Level H  
H Detail Level L  
V Detail Level L  
Detail Band  
Top cut  
OFF  
Iris,Shutter, Auto Iris Adjust  
Gain Set  
Shutter Mode  
Step/Synchro  
Gain  
Step Detail Set 1  
OFF  
0dB  
–––  
5
Noise Suppress  
Level Dependent  
Dark Detail  
3
0%  
0
AGC Max Gain  
Chroma Level  
White Bal  
ATW Speed  
Pedestal  
Painting R Gain  
B Gain  
+2  
AWC A  
Chroma Detail  
0
OFF  
OFF  
––– Detail Set 2 Flesh Noise Suppress  
0
0
0
0
0
Precision Detail  
Color Set  
R Pedestal  
B Pedestal  
H Phase  
SC Coarse  
SC Fine  
Color Bar Set  
Color Bar Set2  
0
1
G/L, Color  
Bar Set  
0
7.5 IRE  
0.0 IRE  
-55-  
Setting to initial set  
Item  
User mode  
Item  
User mode  
B_Mg Gain  
B_Mg Phase  
Mg Gain  
Mg Phase  
Mg_R Gain  
Mg_R Phase  
0
0
Gamma  
0.45  
88%  
110%  
0
Knee Point  
White Clip  
Flare R  
+27  
0
Other Set 1  
0
0
Flare G  
Flare B  
Black Stretch  
Clean DNR  
0
0
OFF  
OFF  
R
R
Gain  
+15  
0
Phase  
R_Yl Gain  
R_Yl Phase  
Yl Gain  
Yl Phase  
Yl_G Gain  
Yl_G Phase  
0
0
Field/Frame  
Baud Rate  
Component  
Aspect Ratio  
Fan SW  
Field  
9600bps  
Y/Pr/Pb  
16:9  
Auto  
(English)  
+18  
+6  
0
Other Set 2  
Color  
Matrix Set  
0
Language  
G
G
Gain  
Phase  
+30  
+112  
0
G_Cy Gain  
G_Cy Phase  
Cy Gain  
Cy Phase  
Cy_B Gain  
Cy_B Phase  
0
Note  
+44  
–15  
0
When the optional card is inserted to the camera,  
“Language” menu will not be returned to default setting  
even if “Initialize Data” menu is executed.  
0
–20  
+36  
B
B
Gain  
Phase  
-56-  

Radio Shack 10M User Manual
Pioneer AVIC F7010BT User Manual
Philips VidQuad Color Video Processors TC8277 User Manual
Panasonic Blu ray Player DMP BDT500 User Manual
Panasonic AJ E User Manual
MTX Audio MTX Thunder TA92001 User Manual
Magnadyne LS4000S LS4001W User Manual
KitchenAid 4KFP710 User Manual
Kenwood KDC 3028 User Manual
JVC GZ MS120AU User Manual